CERTA heavy channel system

KE heavy channel.

Corrosion protection: hot-dip galvanized

Application: Constructing beams (horizontal). Constructing pillars. Constructing various frames and spatial structures using other system components (connectors, supports, brackets, rungs)

Installation method: Installation of CERTA system components to the KE channel is carried out as follows:- in case of elements installed inside the channel through longitudinal holes, - in case of elements installed outside through Ø9.1 mm round holes One hole is intended for only one self-threading bolt. The number of bolts used for installation depends on the type of product being installed. Tighten the XPCSPM10X21 bolt with a torque of 60 Nm

K cantilever arm for KE channel .

Corrosion protection: hot-dip galvanized

Application: installation to the building structure (wall, floor, ceiling). Installation to profile structures. Creation of spatial structures fixed to the building structure (wall, floor, ceiling) or to other KE profile structures.

Installation method: The CERTA system element installed outside the KE profile is fixed through slotted holes (in the base of the element) using XPCSPM10X21 self-tapping screws inserted into Ø9.1 mm round holes in the profile. In case of installation with anchoring, fastening is carried out through round holes using two anchors. One hole is intended for only one self-tapping screw. Tighten the XPCSPM10X21 screw with a torque of 60 Nm. The bracket is supplied complete with a plug.

K200 cantilever arm for KE channel .

Corrosion protection: hot-dip galvanized

Application: installation onto the building structure (wall, floor, ceiling, steel girder). Construction of three-dimensional structures attached to the building structure (wall, floor, ceiling, steel girder).

Installation method: In the case of installation using anchoring, the element is fixed through four round holes using appropriately selected mounting anchors. Alternatively, installation to a steel girder is possible using four KLM cast iron clamps. The bracket is supplied complete with an end cap.

S support for KE channel.

Corrosion protection: hot-dip galvanized

Application: Installation with a KE heavy channel into the structure of the building (wall, floor, ceiling). Installation with a KE heavy channel into a structure made of channels. Creating various structures (such as gates) or spatial structures, attached to the structure of the building (wall, floor, ceiling) or to other structures made of KE channels

Installation method: The CERTA system element installed on the outside of the KE channel is bolted through slotted holes (in the support for the element) using XPCSPM10X21 self-threading bolts fastened into Ø9.1 mm round holes in the channel. One hole is intended for only one self-threading bolt. Products installed on the outside of the channel should be fastened with four bolts. Tighten the XPCSPM10X21 bolt with a torque of 60 Nm. Use two bolts opposite each other for the fastener mounted inside the channel.

S200 support for KE channel.

Corrosion protection: hot-dip galvanized

Application: Installation with a KE heavy channel into the structure of the building (wall, floor, ceiling). Installation with a KE heavy channel into a structure made of channels. Creating various structures (such as gates) or spatial structures, attached to the structure of the building (wall, floor, ceiling) or to other structures made of KE channels

Installation method: The CERTA system element installed on the outside of the KE channel is bolted through slotted holes (in the support for the element) using XPCSPM10X21 self-threading bolts fastened into Ø9.1 mm round holes in the channel. One hole is intended for only one self-threading bolt. The number of bolts used for installation depends on the type of product being installed. Tighten the XPCSPM10X21 bolt with a torque of 60 Nm. Use two bolts opposite each other for the fastener mounted inside the channel.

SK45 channel support for KE channel.

Corrosion protection: hot-dip galvanized

Application: Installation with a heavy channel into the structure of the building (wall, floor, ceiling) at an angle of 45 degrees. Installation with a heavy channel into the structure made of channels at an angle of 45 degrees

Installation method: The CERTA system element installed on the outside of the channel is attached through longitudinal holes (in the support for the element) with XPCSPM10X21 self-threading bolts fastened into Ø9.1mm round holes in the channel. One hole is intended for only one self-threading bolt. Products installed on the outside of the channel should be fastened with four bolts. Tighten the XPCSPM10X21 bolt with a torque of 60 Nm. Use two bolts opposite each other for the fastener mounted inside the channel.

LKZ corner connector for KE channel.

Corrosion protection: hot-dip galvanized

Application: For perpendicular connecting of KE heavy channels.. An additional hole allows stays to be constructed for the purpose of reinforcing the footing. For perpendicular connecting of brackets to KE heavy channels

Installation method: The CERTA system element installed on the outside of the KE channel is bolted through slotted holes (in the support for the element) using XPCSPM10X21 self-threading bolts fastened into Ø9.1 mm round holes in the channel. One hole is intended for only one self-threading bolt. Tighten the XPCSPM10X21 bolt with a torque of 60 Nm.

SN support for KE channel.

Corrosion protection: hot-dip galvanized

Application: assembly with a structural profile for the object’s structure (wall, floor, ceiling). assembly with a structural profile for a profile-based structure. creation of various structures (such as a gate) or spatial ones, mounted to the object’s structure (wall, floor, ceiling) or to other profile-based structures (ke profiles). the placement of the connector allows for installation at the edge.

Installation method: mounted on the outside of the ke profile, the CERTA system element is screwed through longitudinal holes (in the base of the element) with self-tapping screws xpcspm10x21, which are screwed into round holes Ø9.1 mm in the profile. one hole is intended for only one self-tapping screw. products mounted on the outside of the profile should be screwed with four screws. the xpcspm10x21 screw should be tightened with a torque of 60 nm. for the connector mounted inside the profile, use two screws opposite each other.

LT connector for KE channel.

Corrosion protection: hot-dip galvanized

Application: For perpendicular connecting of KE heavy channels

Installation method: The CERTA system element installed on the outside of the channel is bolted through slotted holes with XPCSPM10X21 self-threading bolts fastened into Ø9.1 mm round holes in the channel. One hole is intended for only one self-threading bolt. Fasten the fitting to the outside of the channels with eight bolts. Tighten the XPCSPM10X21 bolt with a torque of 60 Nm.

LK connector for KE channel.

Corrosion protection: hot-dip galvanized

Application: For perpendicular connecting of KE heavy channels.. An additional hole allows stays to be constructed for the purpose of reinforcing the footing. For perpendicular connecting of brackets to KE heavy channels

Installation method: The CERTA system element installed on the outside of the channel is bolted through slotted holes with XPCSPM10X21 self-threading bolts fastened into Ø9.1 mm round holes in the channel. One hole is intended for only one self-threading bolt. Fasten the bracket with a minimum of six self-threading bolts using the slotted holes. Tighten the XPCSPM10X21 bolt with a torque of 60 Nm.

Beam clamp KLM for KE channel.

Corrosion protection: hot-dip galvanized

Application: Installation with a KE heavy channel into the structure of the building (wall, floor, ceiling). Installation with a KE heavy channel into a structure made of channels

Installation method: Place a U-bolt around the KE channel and secure it to the structural profile with a clamp by tightening two nuts.

LW channel connector for KE channel.

Corrosion protection: hot-dip galvanized

Application: Butt connecting of KE heavy channels. Butt connecting of consoles to KE heavy channels

Installation method: Installed inside the KE channel, it is fastened through slotted holes in the channel to round holes in the connector. The connector should be evenly distributed within the channel — both channels connected should have the same number of holes with the same length. Bolt each channel with four bolts, two opposite each other.